Main page | Journal list | Log-in

Ling-Yan Chen, Peng Zhao, Xingsheng Shu, Jie Shen, Yuedong Meng

On the mechanism of atmospheric pressure plasma plume

Physics of Plasmas 17 (2010) 000

For the purpose of unveiling the parameters influencing the length of atmospheric pressure plasma plume, an over 165 cm long argon plasma plume is generated in the quartz tube attached to the nozzle of the device. Dependence of plasma length on discharge parameters such as applied voltage, frequency of power supply, and argon gas flow rate was investigated. Experimental results indicated that (a) the applied voltage plays crucial roles on plasma plume length, that is, the plasma plume length exponentially increases with the applied voltage, (b) the plasma plume length increases with frequency, more obviously when the applied voltage is higher, (c) the plasma plume length increases with argon gas flow rate, reaches its maximum at critical value of the gas flow rate, and then decreases again. An evaluation of the physical phenomena involved in streamer propagation, particularly of the energy balance, was investigated. The numerical results were qualitatively consistent with previous experimental results by successfully indicating the high velocity of “plasma bullet” and providing physical mechanism of energy balance determining streamer length. (C) 2010 American Institute of Physics. {[}doi:10.1063/1.3465665]

This article may also be available to you online

Cited Articles

  1. Janča J., Klíma M., Slavíček P., Zajíčková L.,
    HF Plasma Pencil - New Source for Plasma Surface Processing,
    Surface and Coatings Technology 116 (1999) 547–551